Differences between revisions 1 and 21 (spanning 20 versions)
Revision 1 as of 2011-02-04 18:31:10
Size: 265
Editor: SteveLudtke
Comment:
Revision 21 as of 2011-03-02 00:48:40
Size: 1595
Editor: jgalaz
Comment:
Deletions are marked like this. Additions are marked like this.
Line 1: Line 1:
== Single Particle Tomography in EMAN2 == Single Particle Tomography in EMAN2
Line 3: Line 4:
SPT (single particle tomography) capabilities are relatively new in EMAN2. They were inspired by Michael Schmid's studies on sub-volume averaging (mostly on viruses), and a stubborn student insisting on doing extensive sub-volume averaging on chaperons.
Line 4: Line 6:
This is a relatively new feature in EMAN2, and is ... This session will cover the beta version of a small fraction of the SPT capabilities EMAN2 will eventually make available.
Line 6: Line 8:
The software is provided as part of EMAN2 (already installed) The session will cover:
{{{
`monospace`
}}}
 * 1) SPT processing through EMAN2's workflow: e2workflow.py
 * 2) Sub-volume extraction from tomograms using e2tomoboxer.py
 * 3) "Preparation" of extracted particles for alignment
{{{#!wiki caution
Line 8: Line 17:
We have prepared some sample data For a myriad of reasons, it is NOT recommendable to align and average sub-volumes directly after extraction.
}}}
 * 4) Reference based alignment and averaging
Line 10: Line 21:
[[attachment:spt_demo_2011.tgz]] All necessary software is provided as part of EMAN2. If you don't have EMAN2 installed, you can download the most updated version (for your specific platform, Windows, Linux or Mac), from here: http://ncmi.bcm.edu/ncmi/software/counter_222/software_86

We have prepared sample data for this tutorial. The tomogram in the link below comes from a tilt series of epsilon15 virus particles in vitro, recorded using Zernike phase-plate technology:

[[attachment:e15phaseplate.rec]]

The following tomogram also comes from a tilt series of epsilon15 viruses in vitro but was recorded under conventional cryoEM imaging conditions:

[[attachment:e15normal.rec]]

{{attachment:imagefile.png|text describing image|width=100}}

Single Particle Tomography in EMAN2

Wed PM Practical

SPT (single particle tomography) capabilities are relatively new in EMAN2. They were inspired by Michael Schmid's studies on sub-volume averaging (mostly on viruses), and a stubborn student insisting on doing extensive sub-volume averaging on chaperons.

This session will cover the beta version of a small fraction of the SPT capabilities EMAN2 will eventually make available.

The session will cover:

`monospace`
  • 1) SPT processing through EMAN2's workflow: e2workflow.py
  • 2) Sub-volume extraction from tomograms using e2tomoboxer.py
  • 3) "Preparation" of extracted particles for alignment

For a myriad of reasons, it is NOT recommendable to align and average sub-volumes directly after extraction.

  • 4) Reference based alignment and averaging

All necessary software is provided as part of EMAN2. If you don't have EMAN2 installed, you can download the most updated version (for your specific platform, Windows, Linux or Mac), from here: http://ncmi.bcm.edu/ncmi/software/counter_222/software_86

We have prepared sample data for this tutorial. The tomogram in the link below comes from a tilt series of epsilon15 virus particles in vitro, recorded using Zernike phase-plate technology:

e15phaseplate.rec

The following tomogram also comes from a tilt series of epsilon15 viruses in vitro but was recorded under conventional cryoEM imaging conditions:

e15normal.rec

Ws2011/Spt (last edited 2012-07-05 01:16:47 by jgalaz)