eman2:e2tomosmall
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
eman2:e2tomosmall [2025/08/05 00:57] – steveludtke | eman2:e2tomosmall [2025/08/05 11:06] (current) – [Particle extraction (~2 min (a few manual) - hours (a couple of thousand))] steveludtke | ||
---|---|---|---|
Line 169: | Line 169: | ||
* The image at the top is the central slice through the tomogram | * The image at the top is the central slice through the tomogram | ||
* the //show2d// button displays the selected tomogram in a slice-wise view. | * the //show2d// button displays the selected tomogram in a slice-wise view. | ||
- | * //!ShowTilts// shows the corresponding raw tilt series | + | * // |
* Please note that most tomograms include some out-of-plane tilt (the actual rotation isn't a simple tilt along a single axis), which is taken into account during alignment. This may make it visually appear that the tilt series alignment is not as robust as it actually is. | * Please note that most tomograms include some out-of-plane tilt (the actual rotation isn't a simple tilt along a single axis), which is taken into account during alignment. This may make it visually appear that the tilt series alignment is not as robust as it actually is. | ||
* //Boxer// opens the 3D particle picker | * //Boxer// opens the 3D particle picker | ||
- | * //!PlotLoss// will plot the fiducial error for each tilt | + | * // |
- | * //!PlotCtf// plot the defocus and phase shift at the center of each tilt image | + | * //PlotCtf// plot the defocus and phase shift at the center of each tilt image |
* // | * // | ||
* You can adjust //X Col// and //Y Col// in the plot control panel (middle click the plot). The columns represent: | * You can adjust //X Col// and //Y Col// in the plot control panel (middle click the plot). The columns represent: | ||
Line 198: | Line 198: | ||
This is the easiest approach by far, and is basically a single step process, but is only available in recent (2022+) snapshots of EMAN2. | This is the easiest approach by far, and is basically a single step process, but is only available in recent (2022+) snapshots of EMAN2. | ||
* You should easily be able to select ~500 particles per tomogram, potentially more, but 500 is more than sufficient for the tutorial | * You should easily be able to select ~500 particles per tomogram, potentially more, but 500 is more than sufficient for the tutorial | ||
- | * For instructions, | ||
- | * When complete, skip ahead to the next major section **Particle Extraction** | ||
+ | {{https:// | ||
+ | |||
+ | - Subtomogram Averaging → Convnet based auto-boxing | ||
+ | * label: **ribo** | ||
+ | * gpuid: **-1** //if you don't have a GPU, otherwise use default// | ||
+ | - **Launch** | ||
+ | - Four windows will appear: " | ||
+ | - The " | ||
+ | - Click on tomob. This will cause a window showing the central section of the tomogram to appear. You will need this a lot, so move it somewhere where it is accessible, but doesn' | ||
+ | - Next to the " | ||
+ | - The goal is to select a few (~5 - 20) regions with a ribosome particle well centered in the middle of the circle (which will appear when you click). | ||
+ | * Each time you click, the corresponding region will appear in the (Positive) window | ||
+ | * Holding shift and clicking will remove a reference already selected. | ||
+ | * Using the up/down arrows in the tomogram view will allow you to move up and down through the Z slices of the tomogram. | ||
+ | - Once you have selected 5 or more well centered particles, Change "Good References" | ||
+ | - Use the arrow keys to move " | ||
+ | * Do **not** select very high contrast " | ||
+ | * Instead, select regions of background which contain nothing at all, or weak features which don't look like a particle. | ||
+ | * Again, select 5 or more of these background regions, which will appear in the (Negative) window. | ||
+ | - Once you're happy with your references, hit the **Train** button. | ||
+ | - Bring the terminal window where you launched the project manager to the front. As it trains you will see a series of lines like: " | ||
+ | - Assuming the number decreases to a reasonable value (<1.0). You probably got a pretty decent result. | ||
+ | - Change "Bad References" | ||
+ | - You should see some particles appear in both the tomogram (you may need to move up and down) and the (particles) window. The table will tell you how many were found. | ||
+ | - If the particles look ok, but the number found is significantly less than the ~500 you should be able to get, try reducing " | ||
+ | - If you are satisfied with the results on this Tomogram, press **Save** to save the network, then press **ApplyAll** to box out all 3 Tomograms. | ||
+ | - When complete, skip ahead to the next major section **Particle Extraction** | ||
+ | |||
+ | < | ||
+ | See: [[EMAN2: | ||
+ | </ | ||
==== Tomogram annotation (GPU recommended) ==== | ==== Tomogram annotation (GPU recommended) ==== | ||
- | {{http:// | + | This is an older strategy using the deep-learning based tomogram annotation program to find particles. It still works, but the new deep-learning picker in the section above will generally work better. |
+ | |||
+ | {{https:// | ||
* Since the tutorial data set is purified ribosomes, this step can be skipped for the tutorial data, and you can move on to template-based particle picking. For cells or other types of complex specimens, tomogram annotation can be used to more easily distinguish locations of different types of objects. | * Since the tutorial data set is purified ribosomes, this step can be skipped for the tutorial data, and you can move on to template-based particle picking. For cells or other types of complex specimens, tomogram annotation can be used to more easily distinguish locations of different types of objects. | ||
Line 253: | Line 284: | ||
* If you did the previous optional annotation step above, you will be able to see the selected particles here, and if you like, manually update them. | * If you did the previous optional annotation step above, you will be able to see the selected particles here, and if you like, manually update them. | ||
- | ===== Particle extraction (~2 min (a few manual) - hours (a couple of thousand)) ===== | + | ===== Particle extraction (~2 min (a few manual) - over an hour (a couple of thousand, large tutorial)) ===== |
Note that this step will be vastly different resource-wise if you are only extracting a few manually selected particles for purposes of later template matching or if you already selected hundreds of particles from each tomogram. | Note that this step will be vastly different resource-wise if you are only extracting a few manually selected particles for purposes of later template matching or if you already selected hundreds of particles from each tomogram. | ||
+ | |||
+ | < | ||
+ | Depending on how you selected particles you may have a significant number of particles which contain fiducials or artifacts from the fiducials (bright spots). Having these in your particle data can cause significant problems, and could lead to getting bad initial models and thus bad refinements. For a small data set like this, it might be a good idea to open the manual boxer for each tomogram and delete any particles with fiducials in them before completing this step (particle extraction). | ||
+ | </ | ||
The reduced 1k x 1k (or 2k) tomograms are used only as a reference to identify the location of the objects to be averaged. Now that we have particle locations, the software returns to the original tilt-series, | The reduced 1k x 1k (or 2k) tomograms are used only as a reference to identify the location of the objects to be averaged. Now that we have particle locations, the software returns to the original tilt-series, | ||
Line 264: | Line 299: | ||
* set // | * set // | ||
* If you had the correct size in the previous step this should be the same as leaving the default -1 | * If you had the correct size in the previous step this should be the same as leaving the default -1 | ||
- | * enter the label you used when picking particles (" | + | * enter the label you used when picking particles (" |
* //threads// = value for your machine | * //threads// = value for your machine | ||
* Launch | * Launch | ||
Line 315: | Line 350: | ||
Once it gets past 3-4 iterations, you can use the browser to look in // | Once it gets past 3-4 iterations, you can use the browser to look in // | ||
+ | |||
+ | Note that while the program converges pretty quickly, it won't always get the correct structure, particularly if you have some bad particles (like fiducials) included in the particle set. It is important to look at the resulting starting map and make sure it looks at least vaguely like you expect. If not you may wish to try running this step again. This will produce // | ||
<note tip> | <note tip> |
eman2/e2tomosmall.1754355465.txt.gz · Last modified: by steveludtke