22712
Comment:
|
24192
|
Deletions are marked like this. | Additions are marked like this. |
Line 18: | Line 18: |
* Import tilt series using '''Raw Data -> Import tilt series''' | * '''Raw Data -> Import tilt series''' |
Line 26: | Line 26: |
== Tomogram reconstruction == To first look at the performance of the program, it is useful to start from one representative tilt series and turn off the '''notmp''' option, so temporary files will be written to '''tomorecon_XX'''. While default parameters work in most cases, slightly tweaking the parameters may produce more optimal results. In the '''tomorecon_XX''' folder, '''landmark_0X.txt''' has the location of the landmarks used at each iteration, and '''samples_0X.hdf''' shows the top and side view of those landmarks. '''ptclali_0X.hdf''' has the trace of each landmark throughout the tilt series (they should stay at the center of image all the time if the alignment is good), and '''tomo_0X.hdf''' is the reconstruction after each iteration. |
== Tiltseries Alignment and Tomogram Reconstruction (20 min) == Alignment of the tilt-series is performed iteratively in conjunction with tomogram reconstruction. Tomograms are not normally reconstructed at full resolution, generally limited to 1k x 1k or 2k x 2k, but the tilt-series are aligned at full resolution. For high resolution subtomogram averaging, the raw tilt-series data is used, based on coordinates from particle picking in the downsampled tomograms. On a typical workstation reconstruction takes about 4-5 minutes per tomogram. For the tutorial tilt-series: * '''3D Reconstruction -> Reconstruct Tomograms''' * check ''alltiltseries'' * alternatively you can select one or more tilt series from the ''tiltseries'' folder * check ''correctrot'' * ''tltstep'' = 2 * ''clipz'' = 64 * If you wish to look at the intermediate aligned tilt-series and other files, uncheck ''notmp'' * This is not required for the remaining steps in the tutorial, but can be used to help understand how the tomogram alignment works. This requires significant additional disk space. You may consider doing this for only one tomogram. * In each ''tomorecon_XX'' folder * ''landmark_0X.txt'' has the location of the landmarks (which may be fiducials if present) in each iteration * ''samples_0X.hdf'' shows the top and side view of those landmarks * ''ptclali_0X.hdf'' has the trace of each landmark throughout the tilt series (they should stay at the center of image all the time if the alignment is good) * ''tomo_0X.hdf'' is the reconstruction after each iteration * Launch |
Line 32: | Line 47: |
Make sure to set '''tltstep''' to be the angle between each tilt. While the program can automatically compute the rotation of tilt axis, it is still better to fill in the correct value in '''tltax''' since there is a handedness ambiguity of the tomogram generated if the value is not provided. In most cases, the default '''npk''' should work fine and it is not necessary to change the value according to the number of fiducial in images. When there is fewer (or no) fiducial in the tilt series, the program will use other high contrast objects as landmarks. We highly recommend using output size of 1K and 2K which can be specified with the '''outsize''' option. In our experience, this is enough for visualization, annotation and particle picking. For subtomogram averaging, full-sized particles will be generated from tilt series in the later steps. Although 4K output option can also be specified from the command line, and the program is capable of generating 4K tomograms, it is generally unnecessary and takes much more CPU time, memory and storage. In general, enabling '''bytile''' option can produce visually better results and make the reconstruction run faster. With this option, the program will generate tomogram in small tiles and merge them in real space. Note that the reconstruction process is memory intensive when the output size is 2K or larger. The program will print out the total memory required during reconstruction, so make sure the computer has enough memory for the process. When the sample is thin, it is useful to check '''correctrot''' to automatically position tomograms flat in ice. It also can be helpful to specify a '''clipz''' value to generate thinner tomograms. When the sample is thick, consider check '''normslice''', which can compensate the weaker contrast at the top and bottom of the tomogram. After satisfied with the parameter selections, we can proceed to the whole dataset, simply check '''alltiltseries''' and uncheck '''notmp''' to reconstruct all tomograms sequentially. For the EMPIAR example, the easist way is to check '''alltiltseries''', fill in '''2''' in '''tltstep''', and '''64''' in '''clipz''', check '''correctrot''', leave everything else as default and click '''Launch'''. If it is the first time you use the workflow, it is still recommended to start from one tilt series and uncheck '''notmp''' to look at intermidiate results and play with different options as described earlier. == CTF correction == For this example, simple go to '''CTF correction''', check '''alltiltseries''' and launch the program. For general applications, make sure the '''voltage''' and '''cs''' is correct for your microscope. The first two options, '''dfrange''' and '''psrange''' indicate the defocus and phase shift range to search. They take the format of “start, end, step”, so “2, 5, .1” will search defocus from 2 to 5 um with a step size of 0.1. Unit for phase shift is degree. For defocused micrographs, we usually search a range slightly larger than the target defocus range. For images taken with volta phase plate, we usually have '''dfrange''' of “0.2,2,0.1” and '''psrange''' of “60,120,2”. The program estimates the CTF taking the tilt angle of each image into consideration, so it only works after tomograms are reconstructed in EMAN2. Note in this case, the program only determines the defocus of each tilt-image, but does not correct for the CTF, so it will not affect the tomograms. CTF correction will be done at a per particle per tilt level in the later steps. == Tomogram annotation == |
When working with your own data: * Either specify the correct ''tltstep'' if the tilt series is in order from one extreme to the other, '''or''' specify the name of a ''rawtlt'' file (as produced by serialem/IMOD). * While the program can automatically compute the orientation of the tilt axis, it is better to fill in the correct value in ''tltax'' since there is a handedness ambiguity in the tomogram if determined automatically. * In most cases, the default ''npk'' should be fine. If fiducials are present, it is not necessary to adjust this number to match the number of fiducials. The program will use any high contrast areas it finds as potential landmarks. * ''bytile'' should normally be selected, as it will normally produce better quality reconstructions at higher speed. If 2k or larger tomograms are created, memory consumption may be high, and you should check the program output for the anticipated RAM usage. * The graphical interface only permits 1k or 2k reconstruction sizes. In our experience this is normally sufficient for segmentation or particle picking. * When the sample is thin (purified protein, not cells), it is useful to check '''correctrot''' to automatically position tomograms flat in ice * It can also be helpful with thin ice to specify a '''clipz''' value to generate thinner tomograms (perhaps 64 or 96 for a 1k tomogram). == CTF Estimation (10 min) == For the tutorial tilt-series: * '''Subtomogram Averaging -> CTF Correction''' * check ''alltiltseries'' * Double check the ''voltage'' and ''cs'' * Launch When working with your own data: * The first two options, ''dfrange'' and ''psrange'' indicate the defocus and phase shift range to search. They take the format of “start, end, step”, so “2, 5, .1” will search defocus from 2 to 5 um with a step size of 0.1. Units for phase shift is degrees. * For images taken with volta phase plate, we usually have '''dfrange''' of “0.2,2,0.1” and '''psrange''' of “60,120,2”. Note that this program is only estimating CTF parameters, taking tilt into account. It is not performing any phase-flipping corrections on whole tomograms. CTF correction is performed later as a per-particle process. This process requires metadata determined during tilt-series alignment, so it cannot be used with tomograms reconstructed using other software packages. == Tomogram annotation (optional) == |
Line 58: | Line 74: |
While it is unnecessary to automatically annotate the tomograms since the dataset we use for this tutorial are purified ribosomes, and can be easily picked by template matching, we still demonstrate the annotation process here to show how the annotation process connects to the following subtomogram averaging steps. This section is brief and is probably only useful for users familiar with the tomogram annotation protocol already. A more detailed tutorial of the subject can be found in [[http://blake.bcm.edu/emanwiki/EMAN2/Programs/tomoseg| TomoSeg]]. Note that some directory structure and user interfaces have changed in the latest version to keep with new tomogram workflow. You can also skip this section and use the template matching method described later. First, preprocess the tomograms with the '''Preprocess tomograms''' command. This is not always necessary when the tomograms are reconstructed in EMAN2, but may still produce slightly better results. Next, box a few good and bad references in the '''Box training references''' step. We now switched to the new tomogram boxer GUI for particle picking which includes more functionalities. Go through slices along z-axis using '''‘~’''' and '''‘1’''' on the keyboard. You can now have different types of particles in the same tomogram, and add/rename/delete particle set in the set list window. Still, it is better to keep the box size at 64 and shrink the tomogram for features of different sizes. As long as the tomograms are shrunk in EMAN, the boxer will keep track of the correct box sizes and coordinates in different versions of the same tomogram. In this case, we just need two classes of particles, ribo_good, and ribo_bad. When clicking the '''Save''' button, all particles visible (with the box checked in front of the particle name) will be saved into one stack file. So in a more complicated cellular case, for example, one can have particles types of ribosome, microtubule, noise, and save (ribosome + noise) as negative training set for microtubules. The rest of the annotation process remain unchanged, except for now all trained neural networks and training results are saved in the '''neuralnets''' folder, and all segmented maps are in the '''segmentations''' folder. You can now only specify the label of the output file instead of the full file name so the program can keep track of the metadata. Finally, to turn segmented maps into particle coordinates, go to '''Find particles from segmentation''', and input both the tomogram and its corresponding segmentation, and the particles coordinates will be written into the metadata file. Slightly tweaking the threshold parameters may yield better results. Here '''featurename''' will become the label of particles generated. Those particles can be viewed in the particle picking step and processed in the following protocols. == Particle picking == |
* Since the tutorial data set is purified ribosomes, this step can be skipped for the tutorial data, and you can move on to template-based particle picking. For cells or other types of complex specimens, tomogram annotation can be used to produce locations of different types of objects. This section is brief and is only an update to the more detailed tutorial: [[http://eman2.org/Programs/tomoseg| TomoSeg]]. Some directory structure and user interfaces have changed in the latest version to match new tomogram workflow as described here: * '''Segmentation -> Preprocess tomogram''' * This step is not always necessary for tomograms reconstructed in EMAN2, but may slightly improve results. * '''Segmentation -> Box Training References''' * This is a newer interface than previously used for this step. Select a few "Good" (regions containing the feature of interest) and "Bad" (regions not containing the feature of interest) boxes. * "~" and "1" on the keyboard can be used to move along the Z axis. * The new interface permits different types of features to be identified in a single session and in the same tomogram. * If the different features of interest have very different scale, it is always better to keep the box size at 64, and instead rescale the tomogram. As long as the rescaling is done using EMAN2 utilities, the program will correctly keep track of the geometry relative to the original tomogram & tilt series. * if you are doing this with the tutorial data, you would only have 2 classes of particles "ribo_good" and "ribo_bad". * When pressing ''Save'' all visible particles (box checked next to the class name) will be saved * The rest of the annotation process remain unchanged from the original tutorial, except that now, all trained neural networks and training results are saved in the ''neuralnets'' folder, and all segmented maps are in the ''segmentations'' folder. You now only specify the label of the output file instead of the full file name. * Segmentation -> Find particles from segmentation to turn segmented maps into particle coordinates. * Input both the tomogram and its corresponding segmentation, and the particles coordinates will be written into the metadata file. * Slightly tweaking the threshold parameters may yield better results. * ''featurename'' will become the label of particles generated. Those particles can be viewed in the particle picking step and processed in the following protocols. == Particle picking (10-15 min) == |
Line 72: | Line 99: |
Launch the boxer in '''Subtomogram averaging -> Manual boxing''' step. You can also launch it via the '''Tomogram evaluation''' step which is discussed later in this tutorial. Go through slices along z-axis using '''‘~’''' and '''‘1’''' on the keyboard and deleting boxes by holding Shift and click. The boxes are shown as circles, whose radii indicate the distance from the current slice to the center of the particles. You can rename the label of the boxes and create new types of boxes in the '''options''' window. Make sure the label is consistent for the same particle type in different tomograms, as it is used for particle extraction later. The box size can be set in the main window at the left bottom corner, in this case, 45 for the ribosomes (so the unbinned box size is 180). If you have got the particle coordinates from tomogram annotation, just take a look at the automatically generated particles here and remove some obvious bad ones. While you can save 3D particles from the GUI, there is no need to do so in this step. When you are satisfied with the result, simply close the window. You should have ~3000 particles from the 4 tomograms in the dataset. If you skipped the tomogram annotation step, we will pick a few particles here to generate an initial model first, and use the initial model as a reference for template matching. Select 30-50 particles from a tomogram, then close the boxer window. == Particle extraction == In this step, the program will extract unbinned 2D particles from tilt series, perform per particle per tilt CTF correction, then reconstruct individual 3D particles. Select '''Extract particles''' from the left panel, check '''alltomograms''', and specify the label of particle you want to extract. Make sure the label specified here corresponds to the label of particles from the particle boxer. If the box size is correct when you select particles from the GUI, you can leave '''boxsz_unbin''' as -1, so the program will keep that box size. You can adjust the value if you want to change the box size of the extracted particles. If your particles are deeply buried in other densities, using a bigger '''padtwod''' may help, but doing so may significantly increase the memory usage and slow down the process. With CTF information present, it generally does not hurt to check '''wiener''', which filters the 2D particles by SSNR before reconstructing them in 3D. If you want to generate particles without CTF correction, check '''noctf'''. By default, the generated particles will have the same label as they are named in the boxer. If you want to have multiple types of particles, for example, with and without CTF correction, you can specify a different '''newlabel''' each time you launch the program. Specify a binning factor in '''shrink''' to produce downsampled particles if your memory/storage/CPU time is limited, but it may also limit the resolution you achieve at the end. For the EMPIAR example, check '''alltomograms''', and specify the label for the particles (either all ribosome particles or the ones for initial model); click '''Launch'''. Then, go to '''Build set''' in the left panel, check '''allparticles''', and click launch. This will generate particle sets, which are virtual particle stacks that consist of particles with the same label from different tomograms. == Initial model generation == |
* '''Subtomogram averaging -> Manual boxing''' Time above is to manually select 30-50 reference particles. * ''rename'' the set of boxes to "initribo". This will be used as the label in later stages. * Go through slices along z-axis using '''‘~’''' and '''‘1’''' on the keyboard * left click and drag to place and reposition boxes in any of the 3 views * Hold down Shift when clicking to delete existing boxes. * Boxes are shown as circles, which vary in size depending on the Z distance from the center of the particle. * The interface supports different box types within a single tomogram. Each type has a label. Make sure the label is consistent if selecting the same feature in different tomograms. * The box size can be set in the main window at the left bottom corner, for the tutorial, use 45 for ribosomes (the unbinned box size is 180). * If you skipped the tomogram annotation step, we will pick a few particles here to generate an initial model first, and use the initial model as a reference for template matching. * Select 30-50 particles from a tomogram, then close the boxer window. * If you have the particle coordinates from tomogram annotation above, you may still wish to do this step to delete any obviously bad particles. * While you can save 3D particles from the GUI, there is no need to do that here. When you are satisfied with the result, simply close the window. * You should have ~3000 particles from the 4 tomograms in the dataset. == Particle extraction (2 min) == In this pipeline, the full 1k or 2k tomograms are used only as a reference to identify the location of the objects to be averaged. Now that we have particle locations, the software returns to the original tilt-series, extracts a per-particle tilt-series, and reconstructs each particle in 3-D independently. For the tutorial tilt-series: * '''Subtomogram Averaging -> Extract Particles''' * check ''alltomograms'' * set ''boxsz_unbin'' to 180. * If you had the correct size in the previous step this may not be necessary, but it doesn't hurt. * enter the label you used when picking particles ("initribo" if you followed the instructions above) * Launch * '''Subtomogram Averaging -> Build Sets''' * check ''allparticles'' * Launch * This will generate particle sets, which are virtual particle stacks that consist of particles with the same label from different tomograms. For your own data * If the box size is correct when you select particles from the GUI, you can leave ''boxsz_unbin'' as -1, so the program will keep that box size (scaled to the original tilt series) * If your particles are deeply buried in other densities, using a bigger ''padtwod'' may help, but doing so may significantly increase the memory usage and slow down the process. * With CTF information present, it generally does not hurt to check ''wiener'', which filters the 2D particles by SSNR before reconstructing them in 3D. * Specify a binning factor in ''shrink'' to produce downsampled particles if your memory/storage/CPU time is limited, but it will also limit the resolution you can achieve. == Initial model generation (10 - 60 min) == |
Line 89: | Line 141: |
To build an initial model from scratch, simply go to the '''Generate initial model''' step and input the particle list. If you wish the process to be faster, set '''shrink''' to 2-4. It is not necessary to change other options. The program is parallelized, but not in a standard EMAN2 way. To use more cores, you can enter a bigger number in '''batchsize'''. This will not make the program run faster but may make it converge to the correct answer faster. Also using more particles as input won’t make it run faster or slower either, so either input the full particle set if you have them, or the 30-50 particles you pick for the initial model. If the protein is known to be symmetrical, specify the correct '''symmetry'''. The program will not actually apply the symmetry (unless you check the '''applysym''' box, which is not recommended in general), but it will align the initial model to the symmetry axis so the following steps can work. For most situations, the default number of iterations ('''niter''') of 5 is much more than needed. In this ribosome dataset with '''shrink''' 3, the program should converge to a good initial model before the end of the first iteration, usually within 10 minutes. Output files are written in folders called '''sptsgd_XX'''. In the output folder, the file '''output.hdf''' is the current initial model, which is updated after each batch (so 10-20 times per iteration). So it is okay to stop the program early and use the file as an initial model once it looks good enough. While it would be good to have a better early stopping criterion, given the diversity of things in the cell, we have not come up with one yet. == Template matching == If you generated all particles with tomogram annotation already, skip this step. If not, go to '''Reference-based boxing''', click '''Browse''' for '''tomograms''' to select all tomograms, and Browse the initial model generated in the previous step as '''reference'''. Specify the label of the output particles in '''label''' and set a maximum particle number per tomogram in '''nptcl''' (in the EMPIAR example, 800 should be fine), and click '''Launch'''. After the program finishes, take a look at the particle coordinates from '''Manual boxing''' in the project manager or '''Tomogram evaluation''', and manually remove the obvious bad boxes. This may perform worse than the tomogram annotation in excluding ice contamination and fiducial, but should still be fine for purified samples in this example. Once you are satisfied with the boxes, repeat the '''Particle extraction''' step using the label for the full particle set to generate all 3D particles. == Subtomogram refinement == |
While intuitively it seems like, since the particles are already in 3-D, that the concept of an "initial model" should not be necessary. Unfortunately, due to the missing wedge, and the low resolution of one individual particle (particularly from cells), it is actually critical to make a good starting average, and historically it has been challenging to get a good one, depending on the shape of the molecule. This new procedure based on stochastic gradient descent has proven to be quite robust, but it is difficult for the computer to tell when it has converged sufficiently. For this reason, the default behavior is to run much longer than is normally required, and have a human decide when it's "good enough" and terminate the process. If you use a small ''shrink'' value and let it run to completion, it can take some time to run, but this is normally a waste. For the tutorial tilt-series: * '''Subtomogram Averaging -> Generate Initial Model''' * ''particles'' should be set to the sets/ribo.lst file you just created (whatever name you used). * set ''shrink'' to 2 or 4 * 2 will run slower but will produce a more detailed initial model (not really necessary) * increasing ''batchsize'' will use more cores (if you have more than 12), and may cause it to converge to the correct answer in fewer iterations, but each iteration will not become faster. * The default ''niter'' of 5 is typically much more than is required * Launch * You can terminate the job as soon as ''sptsgd_00/output.hdf'' looks reasonable. If you display the progress monitor (4th icon on the right side of the project manager), you can easily kill the job when you're happy. Usually this will take about 10 minutes for the tutorial data. For your own data: * If your particle has known ''symmetry'', specify that [[EMAN2/Symmetry]] * The symmetry you specify will not be imposed on the map unless you also check ''applysym'', but the map will be rotationally aligned so the symmetry axes are in the correct direction, which will make it easier to apply symmetry in later steps. We do not generally recommend checking this box in this step. * setting ''shrink'' to something in the range of 2-4 will make the runtime faster but, depending on the shape, could potentially cause problems. * using more than the minimal 30-50 particles is fine. If you have a very large set of selected particles, go ahead and use them all. This will not slow the process down at all, since it's stochastic. * it is critical that the full sampling box size of the extracted particles divided by ''shrink'' be divisible by 2. If not, the program will crash. == Template matching (5 min) == In this step, we will use the initial model you just produced as a template for finding all of the ribosomes in all 4 tomograms. If you completed the '''Tomogram Annotation''' step above, and have already extracted a full set of 1000+ particles, then you can skip this step, as we already have all of the particles. * '''Subtomogram Averaging -> Reference Based Boxing''' * browse to select ''tomograms''. Select all 4 tomograms. * set ''reference'' to the output.hdf file you produced in the previous step. * set ''label'' to "ribo" * set ''nptcl'' to 800 (the maximum number of particles per tomogram) * Launch * when this finishes, you can use the same '''Manual Boxing''' tool you used before to look at the particles which were selected. You may wish to manually remove any bad particles it selected. For the tutorial data set or other tomograms of purified protein, this process should work pretty well. For cells you might wish to use the '''Tomogram Annotation''' method above. * note that this process stores 3-D particle locations in the appropriate info/* files, but does not extract particles from the micrographs == Particle extraction (~1 hour) == Again, if you already did '''Tomogram Annotation''' above, this step isn't necessary. It is only required if you just did '''Template Matching'''. Since this involves several thousand particles instead of 30-50, it will take quite a lot longer to run. The actual time will depend partially on the speed of your storage. For the tutorial tilt-series: * '''Subtomogram Averaging -> Extract Particles''' * check ''alltomograms'' * set ''boxsz_unbin'' to 180. * set ''label'' to "ribo" * Launch * '''Subtomogram Averaging -> Build Sets''' * check ''allparticles'' * Launch * This will generate particle sets, which are virtual particle stacks that consist of particles with the same label from different tomograms. == Subtomogram refinement (~40 hr * iterations / # cores) == |
Line 103: | Line 195: |
Click '''3D refinement''' from the left panel, and input both the particle set and the initial model generated from the last step as a reference. If there is a symmetry of the protein, make sure it is aligned to the symmetry axis before specifying the correct symmetry. If you are willing to split the even/odd set of particles and do a “gold-standard” refinement, specify a resolution number (usually 30-50) in '''goldstandard''', so information beyond that resolution will be randomized independently in the reference for even and odd set. While it is good to have a reasonable '''mass''' for the molecular weight of protein (in kDa) and '''tarres''' for the target resolution, leaving them as default usually does not hurt. If you have a known structure factor in a .txt file, (you can compute it from a known structure via [[http://blake.bcm.edu/emanwiki/EMAN2/Programs/e2proc3d|e2proc3d.py]]), specify it in '''setsf'''. '''localfilter''' will filter the averaged map by local resolution, which is especially useful when looking at things in cells where parts of proteins can be very flexible. This is almost always good to check when you want to push toward high resoluion. '''pkeep''' controls the fraction of particles that go into the final average. If you know there are many bad particles in the dataset, setting it to be a smaller number may help. Enter the number of threads you want to use in the '''thread''' option. Finally, click '''Launch''' and wait. For this dataset, it can take a few hours on a decent workstation. The results can be seen in the '''spt_XX''' folder. In the folder, '''threed_XX.hdf''' files are the main output map after each iteration, and '''fsc_masked/unmasked/masktight_XX.txt''' files are the FSC curves between even/odd half set under different masking. You should be able to get to 12-15Å resolution (cutoff 0.143) at this step using this dataset. | This step performs a conventional iterative subtomogram averaging using the full set of particles. Typically it will achieve resolutions in the 15-25 A range with a reasonable number of particles. As it involves 3-D alignment of the full set of particles multiple times, it takes a significant amount of compute time. Higher resolutions are achieved in the next stage after this (subtilt refinement). For the tutorial tilt-series: * '''Subtomogram Averaging -> 3D Refinement''' * set ''particles'' to "sets/ribo.lst" * set ''reference'' to "output.hdf" from '''Initial Model Generation''' * set ''goldstandard'' to 30 * set ''mass'' to 3000 * set ''threads'' to the number of CPUs on your machine * Launch Results will gradually appear in spt_XX/ For your own data: * If your molecule has symmetry, you should specify it, but it's important that the alignment reference you provide has been properly aligned to the symmetry axes of whichever symmetry you specify. * ''localfilter'' will use e2fsc.py to compute a local resolution map after each iteration and filter the map accordingly. This is useful for molecules with significant variability. * If you suspect that a large fraction of your particles are "bad" in some way, you may wish to try reducing ''pkeep'', which will hopefully exclude bad particles preferentially over "good" particles. |
Line 109: | Line 217: |
Once the subtomogram refinement finishes, check the final map and FSC curves. In this dataset, you should be able to achieve a resolution of 13-15Å. Now we can refine the orientation of each individual subtilt, i.e. 2D particles from raw tilt series that are reconstructed into to the 3D particles, and push the resolution of the averaged map. Click '''Sub-tilt refinement''', choose the folder of the last subtomogram refinement and launch the program. You will need to specify the '''path''' to the spt_XX directory containing the last completed subtomogram refinement (typically just “spt_00” for example). Additionally, specify the '''iter''' you want to use as a starting point for sub-tilt refinement. If “-1” is specified, the program will attempt to locate the last complete iteration. The default parameters should be generally fine for this dataset, though you may need to alter the '''parallel''' and '''threads''' options to use the number of CPU threads available on your computer. The niters value corresponds to the number of iterations of sub-tilt refinement you wish to perform. '''keep''' controls the fraction of particles that goes into the final map. If you are certain that tilt images beyond a certain angle (for example, 45 degrees) are radiation damaged, you can put 45 in '''maxalt''', and specify a larger keep number. Otherwise, just use '''keep''' 0.5, so the program will judge the quality of subtilt images by their correlation to the averaged map and exclude worst 50% 2D particles. |
With the results of a good subtomogram alignment/average, we are now ready to switch to alignment of the individual particle images in each tilt, along with per-particle-per-tilt CTF correction and other refinements. This is effectively a hybrid of single particle analysis and subtomogram averaging, and can readily achieve subnanometer resolution IF the data is of sufficient quality. The tutorial data set is, but many cellular tomograms, for example, are not collected with high resolution in mind, and even with this sort of refinement will be unable to achieve resolutions better than 10-30 A, depending on the data. This process is completely automatic, based on all of the metadata collected up to this point. While it is possible to perform "subtomogram refinement" with subtomograms from any tomogram, Subtilt Refinement cannot operate properly unless all preceding steps occurred within EMAN2. For the tutorial tilt series: * '''Subtomogram Averaging -> Sub-tilt Refinement''' * ''path'' should be set to the name of one of a "spt_XX" folder to use as a starting point for the refinement * ''iter'' can be -1 to use the last complete iteration in the "spt_XX" folder. Alternatively you can specify a specific iteration to use * ''parallel'' should be "thread:N" where N is the number of cores you wish to use on a single machine. This job can be run on a linux cluster if you like: [[EMAN2/Parallel]]. * ''threads'' should also be set to the number of cores to use on a single machine * Launch For your own data: * ''niters'' is the number of iterations to run. The default of 4 should achieve convergence in most cases. * ''keep'' is the fraction of tilt images to use in the final map. This defaults to 0.5, meaning the worst 1/2 of the tilts for each particle will be discarded. This permits tilts which contain, for example, projections of fiducials or other strong densities, or with large amounts of motion to be automatically excluded in the final reconstruction. * ''maxalt'' specifies the maximum tilt angle to include from each particle. Most tilt series are collected such that the small tilt angles will have the least radiation damage, and very often high tilts suffer from more motion artifacts. If you enter, for example, "45" in this box then tilts <-45 and >45 will be discarded automatically. In most cases ''keep'' will already serve a similar purpose. |
EMAN2 Tomography Workflow Tutorial
- This tutorial is best suited for EMAN2 built after 09/27/2018. Not everything described in the tutorial was functioning yet in the 2.22 release.
This tutorial uses data from EMPIAR: EMPIAR 10064 (only the 4 mixed CTEM tilt series)
- Time estimates for each step are for a well-configured tomography workstation with a high-speed disk, 64+ GB of RAM and 16+ cores.
- The pixel size in the header of the files are incorrect as provided by EMPIAR. The correct Apix value (2.62) should be specified when importing the images.
Prepare input files (~2 minutes)
- Make a new empty folder for the project and 'cd' into that folder
- Make sure any EMAN2 commands you run are executed from within this folder (not any subfolder)
- You may use "Edit Project" from the Project menu to set default values for the project. While not required, it reduces later errors.
- Make sure the workflow mode is set to "TOMO" not "SPR"
Raw Data -> Import tilt series
Select the files, and make sure importation says copy
In this step you should enter the correct A/pix for your data in the apix box. For EMPIAR10064, this is 2.62. For your own data, you need to know this number. In later steps you should be able to use -1 (default) for apix.
If your tilt series isn't a single stack file, but is many individual images instead, you will need to use Generate tiltseries to build an image stack. This is not necessary for the tutorial data.
Once the options are set, press Launch
It is critical that the filenames for your data not contain any spaces (replace with underscore) or periods (other than the final period used for the file extension). "" (double underscore) is also reserved for describing modified versions of the same file, and should not be used in your original files.
Tiltseries Alignment and Tomogram Reconstruction (20 min)
Alignment of the tilt-series is performed iteratively in conjunction with tomogram reconstruction. Tomograms are not normally reconstructed at full resolution, generally limited to 1k x 1k or 2k x 2k, but the tilt-series are aligned at full resolution. For high resolution subtomogram averaging, the raw tilt-series data is used, based on coordinates from particle picking in the downsampled tomograms. On a typical workstation reconstruction takes about 4-5 minutes per tomogram.
For the tutorial tilt-series:
3D Reconstruction -> Reconstruct Tomograms
check alltiltseries
alternatively you can select one or more tilt series from the tiltseries folder
check correctrot
tltstep = 2
clipz = 64
If you wish to look at the intermediate aligned tilt-series and other files, uncheck notmp
- This is not required for the remaining steps in the tutorial, but can be used to help understand how the tomogram alignment works. This requires significant additional disk space. You may consider doing this for only one tomogram.
In each tomorecon_XX folder
landmark_0X.txt has the location of the landmarks (which may be fiducials if present) in each iteration
samples_0X.hdf shows the top and side view of those landmarks
ptclali_0X.hdf has the trace of each landmark throughout the tilt series (they should stay at the center of image all the time if the alignment is good)
tomo_0X.hdf is the reconstruction after each iteration
- Launch
When working with your own data:
Either specify the correct tltstep if the tilt series is in order from one extreme to the other, or specify the name of a rawtlt file (as produced by serialem/IMOD).
While the program can automatically compute the orientation of the tilt axis, it is better to fill in the correct value in tltax since there is a handedness ambiguity in the tomogram if determined automatically.
In most cases, the default npk should be fine. If fiducials are present, it is not necessary to adjust this number to match the number of fiducials. The program will use any high contrast areas it finds as potential landmarks.
bytile should normally be selected, as it will normally produce better quality reconstructions at higher speed. If 2k or larger tomograms are created, memory consumption may be high, and you should check the program output for the anticipated RAM usage.
- The graphical interface only permits 1k or 2k reconstruction sizes. In our experience this is normally sufficient for segmentation or particle picking.
When the sample is thin (purified protein, not cells), it is useful to check correctrot to automatically position tomograms flat in ice
It can also be helpful with thin ice to specify a clipz value to generate thinner tomograms (perhaps 64 or 96 for a 1k tomogram).
CTF Estimation (10 min)
For the tutorial tilt-series:
Subtomogram Averaging -> CTF Correction
check alltiltseries
Double check the voltage and cs
- Launch
When working with your own data:
The first two options, dfrange and psrange indicate the defocus and phase shift range to search. They take the format of “start, end, step”, so “2, 5, .1” will search defocus from 2 to 5 um with a step size of 0.1. Units for phase shift is degrees.
For images taken with volta phase plate, we usually have dfrange of “0.2,2,0.1” and psrange of “60,120,2”.
Note that this program is only estimating CTF parameters, taking tilt into account. It is not performing any phase-flipping corrections on whole tomograms. CTF correction is performed later as a per-particle process. This process requires metadata determined during tilt-series alignment, so it cannot be used with tomograms reconstructed using other software packages.
Tomogram annotation (optional)
- Since the tutorial data set is purified ribosomes, this step can be skipped for the tutorial data, and you can move on to template-based particle picking. For cells or other types of complex specimens, tomogram annotation can be used to produce locations of different types of objects.
This section is brief and is only an update to the more detailed tutorial: TomoSeg. Some directory structure and user interfaces have changed in the latest version to match new tomogram workflow as described here:
Segmentation -> Preprocess tomogram
- This step is not always necessary for tomograms reconstructed in EMAN2, but may slightly improve results.
Segmentation -> Box Training References
- This is a newer interface than previously used for this step. Select a few "Good" (regions containing the feature of interest) and "Bad" (regions not containing the feature of interest) boxes.
- "~" and "1" on the keyboard can be used to move along the Z axis.
- The new interface permits different types of features to be identified in a single session and in the same tomogram.
If the different features of interest have very different scale, it is always better to keep the box size at 64, and instead rescale the tomogram. As long as the rescaling is done using EMAN2 utilities, the program will correctly keep track of the geometry relative to the original tomogram & tilt series.
- if you are doing this with the tutorial data, you would only have 2 classes of particles "ribo_good" and "ribo_bad".
When pressing Save all visible particles (box checked next to the class name) will be saved
The rest of the annotation process remain unchanged from the original tutorial, except that now, all trained neural networks and training results are saved in the neuralnets folder, and all segmented maps are in the segmentations folder. You now only specify the label of the output file instead of the full file name.
Segmentation -> Find particles from segmentation to turn segmented maps into particle coordinates.
- Input both the tomogram and its corresponding segmentation, and the particles coordinates will be written into the metadata file.
- Slightly tweaking the threshold parameters may yield better results.
featurename will become the label of particles generated. Those particles can be viewed in the particle picking step and processed in the following protocols.
Particle picking (10-15 min)
Subtomogram averaging -> Manual boxing Time above is to manually select 30-50 reference particles.
rename the set of boxes to "initribo". This will be used as the label in later stages.
Go through slices along z-axis using ‘~’ and ‘1’ on the keyboard
- left click and drag to place and reposition boxes in any of the 3 views
- Hold down Shift when clicking to delete existing boxes.
- Boxes are shown as circles, which vary in size depending on the Z distance from the center of the particle.
- The interface supports different box types within a single tomogram. Each type has a label. Make sure the label is consistent if selecting the same feature in different tomograms.
- The box size can be set in the main window at the left bottom corner, for the tutorial, use 45 for ribosomes (the unbinned box size is 180).
- If you skipped the tomogram annotation step, we will pick a few particles here to generate an initial model first, and use the initial model as a reference for template matching.
- Select 30-50 particles from a tomogram, then close the boxer window.
- If you have the particle coordinates from tomogram annotation above, you may still wish to do this step to delete any obviously bad particles.
- While you can save 3D particles from the GUI, there is no need to do that here. When you are satisfied with the result, simply close the window.
- You should have ~3000 particles from the 4 tomograms in the dataset.
Particle extraction (2 min)
In this pipeline, the full 1k or 2k tomograms are used only as a reference to identify the location of the objects to be averaged. Now that we have particle locations, the software returns to the original tilt-series, extracts a per-particle tilt-series, and reconstructs each particle in 3-D independently.
For the tutorial tilt-series:
Subtomogram Averaging -> Extract Particles
check alltomograms
set boxsz_unbin to 180.
- If you had the correct size in the previous step this may not be necessary, but it doesn't hurt.
- enter the label you used when picking particles ("initribo" if you followed the instructions above)
- Launch
Subtomogram Averaging -> Build Sets
check allparticles
- Launch
- This will generate particle sets, which are virtual particle stacks that consist of particles with the same label from different tomograms.
For your own data
If the box size is correct when you select particles from the GUI, you can leave boxsz_unbin as -1, so the program will keep that box size (scaled to the original tilt series)
If your particles are deeply buried in other densities, using a bigger padtwod may help, but doing so may significantly increase the memory usage and slow down the process.
With CTF information present, it generally does not hurt to check wiener, which filters the 2D particles by SSNR before reconstructing them in 3D.
Specify a binning factor in shrink to produce downsampled particles if your memory/storage/CPU time is limited, but it will also limit the resolution you can achieve.
Initial model generation (10 - 60 min)
While intuitively it seems like, since the particles are already in 3-D, that the concept of an "initial model" should not be necessary. Unfortunately, due to the missing wedge, and the low resolution of one individual particle (particularly from cells), it is actually critical to make a good starting average, and historically it has been challenging to get a good one, depending on the shape of the molecule. This new procedure based on stochastic gradient descent has proven to be quite robust, but it is difficult for the computer to tell when it has converged sufficiently. For this reason, the default behavior is to run much longer than is normally required, and have a human decide when it's "good enough" and terminate the process. If you use a small shrink value and let it run to completion, it can take some time to run, but this is normally a waste.
For the tutorial tilt-series:
Subtomogram Averaging -> Generate Initial Model
particles should be set to the sets/ribo.lst file you just created (whatever name you used).
set shrink to 2 or 4
- 2 will run slower but will produce a more detailed initial model (not really necessary)
increasing batchsize will use more cores (if you have more than 12), and may cause it to converge to the correct answer in fewer iterations, but each iteration will not become faster.
The default niter of 5 is typically much more than is required
- Launch
You can terminate the job as soon as sptsgd_00/output.hdf looks reasonable. If you display the progress monitor (4th icon on the right side of the project manager), you can easily kill the job when you're happy. Usually this will take about 10 minutes for the tutorial data.
For your own data:
If your particle has known symmetry, specify that EMAN2/Symmetry
The symmetry you specify will not be imposed on the map unless you also check applysym, but the map will be rotationally aligned so the symmetry axes are in the correct direction, which will make it easier to apply symmetry in later steps. We do not generally recommend checking this box in this step.
setting shrink to something in the range of 2-4 will make the runtime faster but, depending on the shape, could potentially cause problems.
- using more than the minimal 30-50 particles is fine. If you have a very large set of selected particles, go ahead and use them all. This will not slow the process down at all, since it's stochastic.
it is critical that the full sampling box size of the extracted particles divided by shrink be divisible by 2. If not, the program will crash.
Template matching (5 min)
In this step, we will use the initial model you just produced as a template for finding all of the ribosomes in all 4 tomograms. If you completed the Tomogram Annotation step above, and have already extracted a full set of 1000+ particles, then you can skip this step, as we already have all of the particles.
Subtomogram Averaging -> Reference Based Boxing
browse to select tomograms. Select all 4 tomograms.
set reference to the output.hdf file you produced in the previous step.
set label to "ribo"
set nptcl to 800 (the maximum number of particles per tomogram)
- Launch
when this finishes, you can use the same Manual Boxing tool you used before to look at the particles which were selected. You may wish to manually remove any bad particles it selected. For the tutorial data set or other tomograms of purified protein, this process should work pretty well. For cells you might wish to use the Tomogram Annotation method above.
- note that this process stores 3-D particle locations in the appropriate info/* files, but does not extract particles from the micrographs
Particle extraction (~1 hour)
Again, if you already did Tomogram Annotation above, this step isn't necessary. It is only required if you just did Template Matching.
Since this involves several thousand particles instead of 30-50, it will take quite a lot longer to run. The actual time will depend partially on the speed of your storage.
For the tutorial tilt-series:
Subtomogram Averaging -> Extract Particles
check alltomograms
set boxsz_unbin to 180.
set label to "ribo"
- Launch
Subtomogram Averaging -> Build Sets
check allparticles
- Launch
- This will generate particle sets, which are virtual particle stacks that consist of particles with the same label from different tomograms.
Subtomogram refinement (~40 hr * iterations / # cores)
This step performs a conventional iterative subtomogram averaging using the full set of particles. Typically it will achieve resolutions in the 15-25 A range with a reasonable number of particles. As it involves 3-D alignment of the full set of particles multiple times, it takes a significant amount of compute time. Higher resolutions are achieved in the next stage after this (subtilt refinement).
For the tutorial tilt-series:
Subtomogram Averaging -> 3D Refinement
set particles to "sets/ribo.lst"
set reference to "output.hdf" from Initial Model Generation
set goldstandard to 30
set mass to 3000
set threads to the number of CPUs on your machine
- Launch
Results will gradually appear in spt_XX/
For your own data:
- If your molecule has symmetry, you should specify it, but it's important that the alignment reference you provide has been properly aligned to the symmetry axes of whichever symmetry you specify.
localfilter will use e2fsc.py to compute a local resolution map after each iteration and filter the map accordingly. This is useful for molecules with significant variability.
If you suspect that a large fraction of your particles are "bad" in some way, you may wish to try reducing pkeep, which will hopefully exclude bad particles preferentially over "good" particles.
Subtilt refinement
With the results of a good subtomogram alignment/average, we are now ready to switch to alignment of the individual particle images in each tilt, along with per-particle-per-tilt CTF correction and other refinements. This is effectively a hybrid of single particle analysis and subtomogram averaging, and can readily achieve subnanometer resolution IF the data is of sufficient quality. The tutorial data set is, but many cellular tomograms, for example, are not collected with high resolution in mind, and even with this sort of refinement will be unable to achieve resolutions better than 10-30 A, depending on the data. This process is completely automatic, based on all of the metadata collected up to this point. While it is possible to perform "subtomogram refinement" with subtomograms from any tomogram, Subtilt Refinement cannot operate properly unless all preceding steps occurred within EMAN2.
For the tutorial tilt series:
Subtomogram Averaging -> Sub-tilt Refinement
path should be set to the name of one of a "spt_XX" folder to use as a starting point for the refinement
iter can be -1 to use the last complete iteration in the "spt_XX" folder. Alternatively you can specify a specific iteration to use
parallel should be "thread:N" where N is the number of cores you wish to use on a single machine. This job can be run on a linux cluster if you like: EMAN2/Parallel.
threads should also be set to the number of cores to use on a single machine
- Launch
For your own data:
niters is the number of iterations to run. The default of 4 should achieve convergence in most cases.
keep is the fraction of tilt images to use in the final map. This defaults to 0.5, meaning the worst 1/2 of the tilts for each particle will be discarded. This permits tilts which contain, for example, projections of fiducials or other strong densities, or with large amounts of motion to be automatically excluded in the final reconstruction.
maxalt specifies the maximum tilt angle to include from each particle. Most tilt series are collected such that the small tilt angles will have the least radiation damage, and very often high tilts suffer from more motion artifacts. If you enter, for example, "45" in this box then tilts <-45 and >45 will be discarded automatically. In most cases keep will already serve a similar purpose.
Tomogram evaluation
This is a tool that helps you visualize your tomograms with their corresponding metadata, and launch other programs from it. It can be found via Analysis and visualization -> Evaluate tomograms. This can be used at any point of the workflow after tomogram reconstruction.
On the left is a list of tomograms in the project. Clicking the header of each column will sort the table by that attribute. #box is the number of boxes in the tomogram, loss is the average fiducial error in nm, and defocus is the average defocus of the tilt series. Do not be scared by large loss values here. Although the relative value of different tomograms (aligned with the same parameters) in the same project are correlated with tiltseries quality, the exact value here is not as meaningful. You can still get a subnanometer resolution subtomogram average from tilt series with a loss larger than 5 nm.
On the right, the image on the top shows the center slice of the tomogram. The Show2D button shows the selected tomogram in slices, ShowTilts shows the corresponding raw tilt series, and Boxer calls the 3D boxer. PlotLoss will plot the fiducial error per each tilt, and PlotCtf plot the defocus and phase shift at the center of each tilt image. Tiltparams is a bit more complicated. It plots a point list with 6 columns and a number of rows corresponding to the images in the selected tilt series. These are the alignment parameters for the tilt series. The columns represent tilt ID, translation along x and y-axis, tilt angle around y, x and z-axis correspondingly. You can adjust X Col and Y Col in the plot control panel (middle click the plot) to change the display. The first panel below the buttons are the types of particle and their numbers in the dataset. Check and uncheck the boxes will affect the number displayed in #box column on the left. The last box is reserved for comments for each tomogram. You can fill in any comments you have for the selected tomogram and it will be saved with other metadata of the tomogram for future references.
Refinement evaluation
This tool helps visualize and compare results from multiple subtomogram refinement runs. Launch it from Analysis and visualization -> Evaluate SPT refinement. In the GUI, you can look at all spt_XX and sptsgd_XX folders and compare their options and resulting maps. Switch between folder type using the menu at top right. Click the header of a column to sort the table by its content. Uncheck items in the list at bottom-right to hide corresponding columns. Clicking ShowBrowser will bring up the e2display.py browser in the folder of the selected row. PlotParams will plot the Euler angle distribution and other alignment parameters. The 8 columns in the plot are three Euler angles (az, alt, phi), translation in x,y,z, alignment score, and missing wedge coverage score. PlotFSCs will plot the FSC curve under tight mask from each iteration.